Double Wavelength Waveplate

Dual wavelength waveplates are THG-PR polarization rotators and used to manage the polarizations of laser beams to obtain maximum conversion efficiency of third harmonic generations (THG), i.e., 1064 nm + 532 nm > 355 nm.

Generally, type I frequency-doubler (oo-> e) + type II frequency-tripler ( oe-> e) will be the best design for THG which needs no polarization rotator. However, when a type II KTP crystal is used as frequency-doubler and type II LBO as frequency-tripler (see the Figure), the laser polarizations coming out from KTP are not optimized for THG. How to change it into its optimum? Z-OPTICS's THG-PR polarization rotator can do it!

Common 1/2 wave phase retardation plate could only rotate the polarization of 532 nm to a specific angle. However, the linear polarization of 1064 nm will be distorted to be elliptical. The THG-PR rotator is specially designed to maintain the linear polarization of 1064 nm (l plate) and change simultaneously 532 nm (l/2 plate) to the angle you need. The THG-PR can be applied to:
1. Type II (SHG) + Type II (THG)
2. Type I (SHG) + Type I (THG)
3. Type II (SHG) + Type I (THG)

Main Specifications:
    Material:
    Crystal Quartz
    Dimension Tolerance:
    +0.0, -0.2 mm
    Flatness:
    <¦Ë/8 @ 632.8 nm
    Surface Quality:
    20-10 scratch and dig
    Retardation Tolerance:
    <¦Ë/300
    Parallelism:
    <1 arc second
    Dual Wavelength AR Coating:
    R<0.2% at fundamental wavelength & R<0.5% at SHG wavelength